Customization: | Available |
---|---|
Control: | CNC |
Filtering Frequency: | Mutliple Filtered |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard air volume: 12,000CMH
Filter Area: 288sqm
No. | Item | Unit | Description | |||||
1 | General | |||||||
· Dehumiditifier Model | CDC12000 | |||||||
· Treatment Air Volume | m³/h | ≥12000 | ||||||
· Filter Area | m2 | 288 | ||||||
· Filter Wind Speed | m/s | 0.8 | ||||||
· Dust Filtering Efficiency | 99.99% | |||||||
· Power Supply | 380V/3Ph/50Hz | |||||||
· Overall Size (W x D x H) | mm | ≤3600x2200x2450 | ||||||
· Weight | kg | 2560 | ||||||
· Total Power Consumption | kW | 15 | ||||||
· Discharge Nozzles (size & quantity) | No | Φ250mm*4 | ||||||
· Equipment Resistance | Pa | 1200 | ||||||
· Discharge Concentration | mg/m³ | ≤80 | ||||||
· Dust Cleaning Method | Automatic Pulse Back Blowing Dust | |||||||
· Air Supply Pressure | Pa | 5~6 | ||||||
· Air Consumption | m³/min | 1.5 | ||||||
2 | Filter Element | |||||||
· Number of Filter Elements | pcs | 24 | ||||||
· Filter Size | mm | Φ350*660 | ||||||
· Material | Fiber | |||||||
· Installation | Horizontal Type | |||||||
· Operating Temperature | ºC | ≤80ºC | ||||||
3 | Electromagnetic Pulse Valve | |||||||
· Type | 1" Right-angle Valve DMF-Z-40S |
|||||||
· Quantity | pcs | 12 | ||||||
4 | Blowing Fan | |||||||
· Power | kW | 15 | ||||||
· Wind Pressure | Pa | 3,350~2,568 | ||||||
· Number of Motors | pcs | 1 |